TF13 Guide to End Treatment/Terminal Systems
Browse End Treatment / Terminal Systems
Click on a column heading to arrange the list in order associated with that attribute.Name / Designator | Image | System Type | Test Specification | Test Level | Functional Type | Alignment | Energy Category | Median Application | Roadside Application | System Length | System Height | Manufacturer | Drawing Status |
SEB01 Box-Beam Terminal, NYSDOT Type IIA |
No image. | Box (B) | AASHTO MASH 2016 | TL-3 | Redirective / Gating | Flared | Non-Energy-Absorbing | No | Yes | 25' [7.62m] < L ≤ 40' [12.19m] | 26" [660mm] < H ≤ 30" [762mm] | Non-Proprietary | No Drawing |
SEB03 WY-BET Wyoming Box Beam End Terminal |
No image. | Box (B) | NCHRP Report 350 | TL-3 | Trinity Highway Products | No Drawing | |||||||
SEB04 WY-BET Wyoming Box Beam End Terminal (Median) |
No image. | Box (B) | NCHRP Report 350 | TL-3 | Trinity Highway Products | No Drawing | |||||||
SEB05 Box Beam BEAT |
![]() |
Box (B) | NCHRP Report 350 | TL-3 | 26" [660mm] < H ≤ 30" [762mm] | Road Systems, Inc. | Review Complete | ||||||
SEB05b MBEAT Terminal |
![]() |
Box (B) | AASHTO MASH 2016 | TL-3 | Redirective / Gating | Tangent | Energy-Absorbing | No | Yes | 10' [3.05m] < L ≤ 25' [7.62m] | 26" [660mm] < H ≤ 30" [762mm] | Road Systems, Inc. | In Review |
SEB06 Box Beam BEAT-MT (Median) |
![]() |
Box (B) | NCHRP Report 350 | TL-3 | 26" [660mm] < H ≤ 30" [762mm] | Road Systems, Inc. | Review Complete | ||||||
SEC01 Cable Guardrail Anchor |
No image. | Cable (C) | NCHRP Report 350 | TL-3 | 26" [660mm] < H ≤ 30" [762mm] | Non-Proprietary | Review Complete | ||||||
SEC07b Brifen Wire Rope End Treatment |
No image. | Cable (C) | NCHRP Report 350 | TL-3 | Brifen USA | No Drawing | |||||||
SEC07e NUCOR Cable End Terminal |
No image. | Cable (C) | NCHRP Report 350 | TL-3 | Multiple | Nucor Steel Marion, Inc. | No Drawing | ||||||
SEC08 ArmorWire End Terminal TL-3 |
![]() |
Cable (C) | NCHRP Report 350 | TL-3 | Valmont Highway | No Drawing | |||||||
SEC09 Safence Cable End Terminal |
No image. | Cable (C) | NCHRP Report 350 | TL-3 | Gregory Highway | No Drawing | |||||||
SEC10 Cable End Terminal Low Tension |
No image. | Cable (C) | NCHRP Report 350 | TL-3 | Non-Proprietary | No Drawing | |||||||
SEC11 Brifen MASH Cable Terminal |
No image. | Cable (C) | AASHTO MASH 2016 | TL-3 | Redirective / Gating | Tangent | Non-Energy-Absorbing | Yes | 25' [7.62m] < L ≤ 40' [12.19m] | H > 33" [838mm] | Brifen USA | In Review | |
SEC12 4-Cable End Terminal TL-3 |
No image. | Cable (C) | AASHTO MASH 2016 | TL-3 | Redirective / Gating | Tangent | Non-Energy-Absorbing | Yes | Yes | 25' [7.62m] < L ≤ 40' [12.19m] | H > 33" [838mm] | Gibraltar Global, LLC | In Review |
SED01 Steel Backed Timber Guardrail Tangent End Terminal |
No image. | Wood (D) | NCHRP Report 350 | TL-2 | Non-Proprietary | No Drawing | |||||||
SEO01a SLED mini to Concrete Barrier |
No image. | Other (O) | AASHTO MASH 2016 | TL-2 | Non-Redirective | Tangent | Energy-Absorbing | Yes | Yes | 10' [3.05m] < L ≤ 25' [7.62m] | 30" [762mm] < H ≤ 33" [838mm] | TrafFix Devices, Inc. | In Review |
SEO01b SLED mini to TrafFix Water Cable Barrier |
No image. | Other (O) | AASHTO MASH 2016 | TL-2 | Non-Redirective | Tangent | Energy-Absorbing | Yes | Yes | L ≤ 10' [3.05m] | 30" [762mm] < H ≤ 33" [838mm] | TrafFix Devices, Inc. | In Review |
SEO02a SLED to MGS Guardrail |
No image. | Other (O) | AASHTO MASH 2016 | TL-3 | Non-Redirective | Tangent | Energy-Absorbing | Yes | Yes | 25' [7.62m] < L ≤ 40' [12.19m] | 30" [762mm] < H ≤ 33" [838mm] | TrafFix Devices, Inc. | In Review |
SEO02b SLED to Sentry II Water Cable Barrier |
No image. | Other (O) | AASHTO MASH 2016 | TL-3 | Non-Redirective | Tangent | Energy-Absorbing | Yes | Yes | L > 40' [12.19m] | 30" [762mm] < H ≤ 33" [838mm] | TrafFix Devices, Inc. | No Drawing |
SEO03a SLED Lo-Ro |
No image. | Other (O) | AASHTO MASH 2016 | TL-2 | Non-Redirective | Tangent | Energy-Absorbing | Yes | Yes | 10' [3.05m] < L ≤ 25' [7.62m] | H > 33" [838mm] | TrafFix Devices, Inc. | In Review |
SEO04a ArmorZone End Treatment MASH TL-2 |
No image. | Other (O) | AASHTO MASH 2016 | TL-2 | Non-Redirective | Tangent | Energy-Absorbing | Yes | Yes | 10' [3.05m] < L ≤ 25' [7.62m] | H > 33" [838mm] | Valmont Highway | In Review |
SEO05a Ermes End Terminal |
No image. | Other (O) | AASHTO MASH 2016 | TL-3 | Redirective / Non-Gating | Tangent | Energy-Absorbing | No | Yes | 10' [3.05m] < L ≤ 25' [7.62m] | 30" [762mm] < H ≤ 33" [838mm] | Industry AMS S.r.l. | In Review |
SER01 Low-Profile Construction-Zone End Treatment |
No image. | Rigid (R) | NCHRP Report 350 | TL-2 | H ≤ 26" [660mm] | Non-Proprietary | No Drawing | ||||||
SER02a Triton Barrier Concrete End Treatment |
![]() |
Rigid (R) | NCHRP Report 350 | TL-2 | Energy Absorption Systems | Review Complete | |||||||
SER02b Triton Barrier Concrete End Treatment |
![]() |
Rigid (R) | NCHRP Report 350 | TL-3 | Energy Absorption Systems | Review Complete | |||||||
SER03 Low-Profile Concrete Barrier End Treatment |
No image. | Rigid (R) | NCHRP Report 350 | TL-2 | H ≤ 26" [660mm] | Non-Proprietary | Review Complete | ||||||
SER04 Florida Low-Profile Barrier Terminal |
No image. | Rigid (R) | NCHRP Report 350 | TL-2 | Redirective / Gating | Tangent | Non-Energy-Absorbing | Yes | Yes | 10' [3.05m] < L ≤ 25' [7.62m] | H ≤ 26" [660mm] | Non-Proprietary | In Review |
SET02 Quadtrend 350 |
![]() |
Thrie-Beam (T) | NCHRP Report 350 | TL-3 | Energy Absorption Systems | Review Complete | |||||||
SET03a Thrie Beam Bull Nose, Wood Post |
![]() |
Thrie-Beam (T) | NCHRP Report 350 | TL-3 | 30" [762mm] < H ≤ 33" [838mm] | Non-Proprietary | Review Complete | ||||||
SET03b Thrie Beam Bull Nose, Steel Post |
No image. | Thrie-Beam (T) | NCHRP Report 350 | TL-3 | 30" [762mm] < H ≤ 33" [838mm] | Non-Proprietary | Review Complete | ||||||
SEW05 Modified Eccentric Loader Terminal (MELT) |
No image. | W-Beam (W) | NCHRP Report 350 | TL-2 | Redirective / Gating | Flared | Non-Energy-Absorbing | No | Yes | 25' [7.62m] < L ≤ 40' [12.19m] | 26" [660mm] < H ≤ 30" [762mm] | Non-Proprietary | Review Complete |
SEW06 Brakemaster 350 |
![]() |
W-Beam (W) | NCHRP Report 350 | TL-3 | 26" [660mm] < H ≤ 30" [762mm] | Energy Absorption Systems | Review Complete | ||||||
SEW08 C-A-T Crash-Cushion/Attenuating Terminal |
No image. | W-Beam (W) | NCHRP Report 350 | TL-3 | Trinity Highway Products | No Drawing | |||||||
SEW12 Slotted Rail Terminal (SRT) |
No image. | W-Beam (W) | NCHRP Report 350 | TL-3 | Trinity Highway Products | No Drawing | |||||||
SEW12c Slotted Rail Terminal (SRT) MASH |
No image. | W-Beam (W) | AASHTO MASH 2016 | TL-3 | Trinity Highway Products | No Drawing | |||||||
SEW14a FLEAT |
![]() |
W-Beam (W) | NCHRP Report 350 | TL-3 | 26" [660mm] < H ≤ 30" [762mm] | Road Systems, Inc. | Review Complete | ||||||
SEW14b FLEAT |
![]() |
W-Beam (W) | NCHRP Report 350 | TL-2 | 26" [660mm] < H ≤ 30" [762mm] | Road Systems, Inc. | Review Complete | ||||||
SEW14c MFLEAT Terminal |
![]() |
W-Beam (W) | AASHTO MASH 2016 | TL-3 | Redirective / Gating | Flared | Energy-Absorbing | No | Yes | 25' [7.62m] < L ≤ 40' [12.19m] | 30" [762mm] < H ≤ 33" [838mm] | Road Systems, Inc. | In Review |
SEW15 FLEAT - MGS System |
![]() |
W-Beam (W) | NCHRP Report 350 | TL-3 | 30" [762mm] < H ≤ 33" [838mm] | Road Systems, Inc. | Review Complete | ||||||
SEW16a FLEAT-MT Median Terminal |
![]() |
W-Beam (W) | NCHRP Report 350 | TL-3 | 26" [660mm] < H ≤ 30" [762mm] | Road Systems, Inc. | Review Complete | ||||||
SEW16b FLEAT-MT Median Terminal for MGS |
![]() |
W-Beam (W) | NCHRP Report 350 | TL-3 | Road Systems, Inc. | No Drawing | |||||||
SEW17a Sequential Kinking Terminal (SKT) |
![]() |
W-Beam (W) | NCHRP Report 350 | TL-3 | 26" [660mm] < H ≤ 30" [762mm] | Road Systems, Inc. | Review Complete | ||||||
SEW17b Sequential Kinking Terminal (SKT) Lite |
![]() |
W-Beam (W) | NCHRP Report 350 | TL-3 | 26" [660mm] < H ≤ 30" [762mm] | Road Systems, Inc. | Review Complete | ||||||
SEW17c Sequential Kinking Terminal (SKT) |
![]() |
W-Beam (W) | NCHRP Report 350 | TL-2 | 26" [660mm] < H ≤ 30" [762mm] | Road Systems, Inc. | Review Complete | ||||||
SEW17d MASH SKT (MSKT) - MGS System |
![]() |
W-Beam (W) | AASHTO MASH 2016 | TL-3 | Redirective / Gating | Tangent | Energy-Absorbing | No | Yes | L > 40' [12.19m] | 30" [762mm] < H ≤ 33" [838mm] | Road Systems, Inc. | In Review |
SEW18a Sequential Kinking Terminal (SKT) - MGS |
![]() |
W-Beam (W) | NCHRP Report 350 | TL-3 | 30" [762mm] < H ≤ 33" [838mm] | Road Systems, Inc. | Review Complete | ||||||
SEW18b Sequential Kinking Terminal (SKT) - MGS Lite |
![]() |
W-Beam (W) | NCHRP Report 350 | TL-3 | 30" [762mm] < H ≤ 33" [838mm] | Road Systems, Inc. | Review Complete | ||||||
SEW19 X-TENSION Guardrail Terminal, Tangent |
No image. | W-Beam (W) | NCHRP Report 350 | TL-3 | 26" [660mm] < H ≤ 30" [762mm] | Lindsay Transportation Solutions | In Review | ||||||
SEW20 X-TENSION Guardrail Terminal, Flared |
No image. | W-Beam (W) | NCHRP Report 350 | TL-3 | 26" [660mm] < H ≤ 30" [762mm] | Lindsay Transportation Solutions | In Review | ||||||
SEW21 X-TENSION Median Guardrail Terminal (XMAS ) |
No image. | W-Beam (W) | NCHRP Report 350 | TL-3 | 26" [660mm] < H ≤ 30" [762mm] | Lindsay Transportation Solutions | In Review | ||||||
SEW22a Soft Stop End Terminal, TL-3 |
No image. | W-Beam (W) | AASHTO MASH 2016 | TL-3 | Trinity Highway Products | No Drawing | |||||||
SEW22b Soft Stop End Terminal, TL-2 |
No image. | W-Beam (W) | AASHTO MASH 2016 | TL-2 | Trinity Highway Products | No Drawing | |||||||
SEW22c Soft Stop End Terminal, TL-1 |
No image. | W-Beam (W) | AASHTO MASH 2016 | TL-1 | Trinity Highway Products | No Drawing | |||||||
SEW23 X-LITE System, Tangent |
No image. | W-Beam (W) | NCHRP Report 350 | TL-3 | Multiple | Lindsay Transportation Solutions | In Review | ||||||
SEW24 X-LITE System, Flared |
No image. | W-Beam (W) | NCHRP Report 350 | TL-3 | Multiple | Lindsay Transportation Solutions | In Review | ||||||
SEW25a TREND End Terminal, Tangent |
No image. | W-Beam (W) | NCHRP Report 350 | TL-3 | Energy Absorption Systems | No Drawing | |||||||
SEW25b TREND End Terminal, Flared |
No image. | W-Beam (W) | NCHRP Report 350 | TL-3 | Energy Absorption Systems | No Drawing | |||||||
SEW26 TREND End Terminal, Median |
No image. | W-Beam (W) | NCHRP Report 350 | TL-3 | Energy Absorption Systems | No Drawing | |||||||
SEW31 Trailing-End Anchorage for 31" Guardrail |
No image. | W-Beam (W) | AASHTO MASH 2016 | TL-3 | Redirective / Gating | Tangent | Non-Energy-Absorbing | No | Yes | 10' [3.05m] < L ≤ 25' [7.62m] | 30" [762mm] < H ≤ 33" [838mm] | Non-Proprietary | In Review |
SEW32a MAX-Tension Guardrail Terminal System, TL-3 |
![]() |
W-Beam (W) | AASHTO MASH 2016 | TL-3 | Redirective / Gating | Tangent | Energy-Absorbing | No | Yes | L > 40' [12.19m] | 30" [762mm] < H ≤ 33" [838mm] | Lindsay Transportation Solutions | Review Complete |
SEW32b MAX-Tension Guardrail Terminal System, TL-2 |
![]() |
W-Beam (W) | AASHTO MASH 2016 | TL-2 | Redirective / Non-Gating | Tangent | Energy-Absorbing | No | Yes | 25' [7.62m] < L ≤ 40' [12.19m] | 30" [762mm] < H ≤ 33" [838mm] | Lindsay Transportation Solutions | Review Complete |
SEW32c MAX-Tension Median Terminal System, TL-3 |
![]() |
W-Beam (W) | AASHTO MASH 2016 | TL-3 | Redirective / Gating | Tangent | Energy-Absorbing | Yes | No | L > 40' [12.19m] | 30" [762mm] < H ≤ 33" [838mm] | Lindsay Transportation Solutions | Review Complete |
SEW33a Buried-in-Backslope (BIB) Terminal |
![]() |
W-Beam (W) | AASHTO MASH 2016 | TL-3 | Redirective / Non-Gating | Flared | Non-Energy-Absorbing | No | Yes | L > 40' [12.19m] | 30" [762mm] < H ≤ 33" [838mm] | Non-Proprietary | In Review |